Black oblique lines

Paralon System

Paralon ARD/S and ARD/HS are APP and SBS modified bitumen polymer waterproofing membranes intended for all waterproofing applications including; Flat Roofs, Terraces, Podiums, Car Parks and Bridge Decks, Tunnels, Foundations and Underground Structures.

The Paralon range of waterproofing membranes, may be used in new build and refurbishment applications and are suitable for applications in low temperature conditions. Paralon remains flexible at low temperatures and exhibits high resistance to thermal stress.

Reinforced Bituminous Membrane (RBM) which is commonly referred to as felt, still remains one of the most widely specified and installed forms of flat roof waterproofing for both new build and refurbishment projects across many market sectors within flat roofing.

There is a broad range of polymer modified felts to choose from to suit different applications.

RBM can accommodate extreme stresses from thermal movement and wind loading, whilst withstanding a higher degree of construction and maintenance traffic, making it an ideal choice for many projects.

Combining bitumen with additives such as Atactic Polypropylene (APP), Styrene Butadiene Styrene (SBS) or a combination of the two, alters the characteristics and performance of the membrane.

The addition of different carriers such as glass fibres, polyester or a blend of both produces a waterproof material on a roll that is easy to install, very strong, and low in cost.

Many developments and improvements have been made over the years, including development of both the bitumen compound, modification of polymers and the reinforcement materials used, originating with materials such as tar paper or asbestos, progressing to safer, higher-quality materials such as glass fibre or more recently polyester.

Polyester is probably one of the biggest improvements for RBM, making membranes extremely resilient, durable and long lasting. Improving the resistance to tearing and impact along with its resistance to withstand foot traffic.

The Paralon membrane performance is obtained by coextrusion of the PARALLOY® compound which combines the best characteristics of SBS and APP compounds, reinforced with a synthetic non-woven continuous filament polyester fabric, enabling plasticity, elastic behaviour and superior resistance to mechanical damage. The membrane is manufactured with a slate granule coating to the upper surface of the membrane, in various colours, offering UV protection and slip resistance. The lower face is coated with Termotene® fusible film which aids unrolling and facilitates torch bonding to various substrates.

The Paralon APP/SBS bitumen compound’s special formulation ensures high mechanical performance, cold flexibility at temperatures down to -20°C and excellent fatigue strength.

Add to Spec

System Build Up

1

Cap Sheet

Uppermost layer of reinforced bitumen membrane which is applied over the base layer as the final exposed waterproofing layer. This will be either the Paralon ARD/S or the Paralon ARD/HS cap sheet, with a slate granule finish to provide UV protection.

2

Base Layer

First layer of reinforced bitumen membrane, installed in the built-up waterproofing system. Paralon TOP/S or Paralon TOP/N will be utilised as appropriate.

3

Insulation

Thermal insulation is an essential component within a warm roof system. Its purpose is to control and maintain the temperature of the building below. It’s important to ensure a sufficient thickness of insulation is installed in order to meet the requirements of the appropriate Building Regulations and local legislation. Other considerations are critical when selecting the type of material used as a thermal insulant, such as its compressive strength and loading capacity, acoustic properties, fire performance and compatibility with the waterproofing system.

4

AVCL

Purpose of the air and vapour control layer is to reduce or control the passage of air and moisture vapour passing from within the building, up through the roofing system, potentially causing risk of interstitial condensation within layers of the roof construction or allowing increased levels of air leakage.

5

Primer

Where applicable an appropriate primer will usually be required prior to the application of a bituminous AVCL over the roof deck.

6

Roof Deck

The structural roof deck spans the structural frame of the building to provide a continuous support for the roofing system and ultimately what the roof is attached to. This may be in the form of a profiled steel, profiled aluminium, concrete or timber deck. All designed to accommodate all anticipated design loadings.

Technical Info

Technical Summary

Colour

Multiple Options available dependent on Specification

Finish

Granular surface

Material

PARALLOY® compound which combines the best characteristics of SBS and APP compounds, reinforced with a synthetic non-woven continuous filament polyester fabric

Shape

Rectangular

Length

1000mm

Width

1000mm

Warranty description

Moy offer duration versatility in warranty dependant of the specification.

Full Technical Detail

For full detailed technical information about this system please download our technical datasheet.

Benefits

Resistance

Extremely resilient, durable and long lasting making Paralon resistant to tearing and impact and as a result capable of withstanding foot traffic. Excellent resistance to punctures and UV degradation.

Extended Warranty

Available with extended system warranties and a service life of up to 40 years.

Certified

British Board of Agrément (BBA) certified, Irish Agrément (NSAI) certified, CE marked, Environmental Product Declaration (EPD) inclusion, Factory Mutual Certified options

Fire Certification

TS 1187 BROOF Regional Fire Certification (consult Moy for guidance).

No Dangerious Substances

Paralon membranes contain no asbestos, tar or other dangerous (red list) substances.

Multiple Colour Options

Paralon System options for Green Roofs, Blue Roofs and multiple colour options, including Highly Solar Reflective Index Rating (SRI) and skid inhibiting surface finishes.

Downloads

  • Download All
  • Declaration of performance

    MOY_PARALON ANTIROOT DoP 051223 v3

  • Declaration of performance

    MOY_TOP N3 DoP 051223 v3

  • Declaration of performance

    MOY_PARALON ARD S DoP 051223 v3

  • Declaration of performance

    MOY_PARALON NT4 DoP 051223 v3

  • Technical data sheets

    MOY_TOP S TDS 140723 v3

  • Declaration of performance

    MOY_PARALON ARD HS DoP 051223 v3

  • Technical data sheets

    MOY_TOP N TDS 140723 v1

All Technical Downloads

For a full list of technical downloads available from MOY see our Technical Downloads page

All Technical Downloads